BTS & Cell Tower Battery Factory
Telecom Battery
Manufacturer48V Systems, 15-20 Year Life
Naradex manufactures telecom backup batteries with -40°C to +55°C operating range,48V string configuration, and15-20 year design life. Built for BTS sites, cell towers, and communication infrastructure worldwide.
- 2V AGM (NL series): 150Ah to 3,000Ah — indoor BTS rooms
- 2V OPzV (tubular gel): 100Ah to 3,000Ah — outdoor cabinets
- OEM / Private Label — your brand, our factory

Telecom Battery Solutions: AGM vs OPzV
Choose the right battery chemistry for your telecom infrastructure. Indoor BTS rooms benefit from AGM cost efficiency, while outdoor cabinets demand OPzV gel durability.
NL2 AGM — Indoor BTS
2V AGM stationary batteries, 150-3,000Ah. 15+ year float life, 800+ cycles at 50% DOD. Cost-effective choice for temperature-controlled telecom shelters and equipment rooms.
OPzV Gel — Outdoor Cabinets
2V tubular gel batteries, 100-3,000Ah. 20+ year design life, 2,000+ cycles at 80% DOD. Zero maintenance for remote BTS sites and outdoor cabinets in harsh climates.
48V String Configuration
24 cells in series for standard 48V telecom DC systems. Battery strings from 100Ah (4.8kWh) to 3,000Ah (144kWh) to match any backup time requirement from 2 to 72+ hours.
-40°C to +55°C Range
OPzV gel electrolyte maintains ionic conductivity in extreme cold and heat. Reliable backup from Arctic base stations to desert cell towers without external temperature management.
Zero Maintenance
Sealed valve-regulated design eliminates water refilling. No acid fumes, no corrosion risk. Install once and forget — critical for unmanned remote telecom sites.
Fast Recharge
High charge acceptance for rapid recovery after grid outages. Optimized plate design enables full recharge within 8-12 hours to prepare for the next power failure event.
AGM vs OPzV for Telecom: Which to Choose?
Both technologies serve telecom backup. Your choice depends on installation environment, budget, and maintenance access.
| Parameter | NL2 AGM (Indoor) | OPzV Gel (Outdoor) |
|---|---|---|
| Design Float Life | 15+ years | 20+ years |
| Cycle Life (80% DOD) | 300-500 cycles | 2,000+ cycles |
| Cycle Life (50% DOD) | 800+ cycles | 3,300+ cycles |
| Temperature Range | -25 to +60°C | -40 to +55°C |
| Maintenance | Zero | Zero |
| Acid Stratification | Possible in tall cells | None (gel electrolyte) |
| Self-Discharge | ≤3% / month | ≤2% / month |
| Capacity Range | 150-3,000Ah | 100-3,000Ah |
| Best For | Indoor BTS rooms, data centers | Outdoor cabinets, remote sites |
| Relative Cost | Lower initial cost | Higher — lower TCO over 20 years |
Telecom Battery Applications
Reliable backup power for every layer of the telecommunications network, from macro cell towers to edge data centers.
BTS / Cell Tower
48V battery banks for 4G/5G base transceiver stations. 8-72 hour backup depending on site tier. Outdoor-rated OPzV for unmanned towers.
Learn more →Data Center
48V DC power for server racks, switches, and cooling. High-capacity NL2 AGM strings for indoor installations with controlled environments.
Learn more →Microwave / Satellite
Remote relay stations and VSAT hubs with extreme temperature swings. OPzV gel handles -40 to +55 degrees C without external HVAC.
Learn more →Fiber Optic / FTTH
Optical line terminals (OLT) and distribution hubs. Compact 12V or 2V configurations for fiber-to-the-home and last-mile infrastructure.
Learn more →Popular Telecom Battery Configurations
Pre-engineered 48V battery strings for common telecom backup requirements. Custom configurations available.
Telecom Battery Factory
Our 20,000 m² factory in Jiangmen, Guangdong Province has been manufacturing VRLA batteries since 2015. With 400+ employees and dedicated telecom battery production lines, we supply to telecom operators and tower companies in 100+ countries with consistent quality and on-time delivery.




How to Order Telecom Batteries
Simple process from inquiry to delivery. We respond within 12 hours.
Send Inquiry
Tell us your telecom backup requirements: voltage, capacity, backup time, and environment conditions.
Get Quote
FOB pricing with full datasheets and string configuration recommendations within 12 hours.
Production
IQC + PQC + OQC quality control. Sample available for testing before bulk order.
Shipping
Stock: 7 days. Full container: 30 days. MSDS certified for international transport.
Telecom Battery Resources
BTS & cell tower power sizing, selection, and installation
VRLA Battery Maintenance: 7 StepsDouble lifespan with proper maintenance protocol
AGM vs Gel Battery: Which Is Better?Choose the right chemistry for indoor vs outdoor BTS
How to Charge AGM Battery: Voltage GuideCorrect rectifier settings for telecom float charging
2V Battery ManufacturerAGM, gel & OPzV cells 100-3,000Ah
AGM Battery Manufacturer12V AGM battery factory capabilities
Telecom Battery — Frequently Asked Questions
What types of batteries does Naradex supply for telecom applications?
Can Naradex telecom batteries operate in extreme temperatures?
What is the typical backup time for a 48V telecom battery system?
How long do telecom batteries last in the field?
What is the MOQ for telecom battery orders?
Do Naradex telecom batteries meet international telecom standards?
Get Telecom Battery Factory Pricing
Whether you need AGM for indoor BTS rooms or OPzV gel for outdoor cell towers, our team designs the optimal battery string for your telecom project.
We reply to all inquiries within 12 hours. Sample orders accepted.